Application: | High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction
AS600 special inverter for crane is designed for the industrial cranes, such as quayside container bridge crane, container gantry crane, portal crane and beam crane. With the use of advanced vector control technology, the product has the same excellent control technology and torque control technology, the product has the same excellent control performance with high-end international inverter and, combined with the application characteristics in the hoisting machinery industry, further strengthens the product output characteristics, reliability and environmental adaptation and can better meet various application requirements of the hoisting machinery.
Technical features
High torque and high load capacity
Power input | Input voltage | (380-460)V(-15% ~ +10%), three phase supply, voltage unbalance <3% | ||
Input frequency | (45-65)Hz | |||
Instantaneous power drop | Under voltage protection when the input voltage is less than AC300V in the power supply AC(380-460)V | |||
Power output | Voltage | OVAC- input voltage | ||
Output frequency | V/F control: (0.00/300.00) Hz, Vector control: (0.00-120.00)Hz | |||
Overload level | Heavy load: 150%,60S; super heavy load: 150%,60S; 200%,2S | |||
Digital IO | Output frequency accuracy | ±0.01%(digital command -10 ~+45ºC); ±0.1%(analog command 25±10ºC) | ||
Opto-isolator input | 7 - channel, 24V active high and low settable and input function definable | |||
Analog input and output | Open collector output | 2 - channel , output functions definable | ||
Relay output | 2 - channel normally open, 2 - channel normally open and normally closed contacts | |||
Analog voltage input | 2 - channel, voltage: (-10~ +10)VDC or current : (0-20)mA optional signal | |||
Analog voltage output | 2 - channel, voltage: (-10~ +10)VDC or current : (0-20)mA optional signal | |||
Encoder input | PG card power | 5V, 12V, 300mA | ||
PG card signal | Open collector, push-pull, differential, SIN/COS incremental, Endat absolute value type, Resover type, orthogonal open collector output and division factor 2/4/8/16/32/64/128 settable(optional) | |||
Control characteristics | Control mode | V/F control | Open-loop vector control | Closed-loop control |
Starting mode | 2.50Hz, 150% | 0.5Hz, 200% | 0.00Hz, 200% | |
Steady speed precision | ±2% | ±0.2% | ±0.02% | |
Torque precision | 5% (closed-loop control) | |||
Torque compensation | Automatic torque compensation and manual torque compensation | |||
V/F curve | User-defined V/F curve, linear V/F curve and 3 reduced torque characteristic curves | |||
Automatic voltage regulation (AVR) | Automatically adjust the duty cycle of PWM signal according to the bus voltage fluctuation | |||
Non-stop at instantaneous stop | Achieve continuous operation through bus voltage control in case of instantaneous power failure | |||
Dynamic braking capacity | Built-in brake unit and external brake resistor (optional) for the power 22kw and below External brake unit (optional) for the power above 22kw. |
|||
DC braking capacity | Braking current : (0.0-120.0% rated current. | |||
Torque control function | Torque/speed control switching through terminals, many torque given models | |||
Zero servo and position control function | Achieve zero speed position lock, accurate positioning and position control. | |||
Common DC bus | The whole series may achieve power supply of many inverters by common DC bus. | |||
Environmental conditions | Usage occasion | Keep out of direct sunlight, dust, corrosive gases, combustible gases, oil mist, water vapor or dropping water. | ||
Environment temperature | (-10~+40)ºC | |||
Altitude | <1000m | |||
Environment humidity | (5-95)%, no condensation allowed | |||
Vibration(installation) | 2≤f<9Hz, 0.3mm; 9≤f<200Hz, 1m/s2 | |||
Protection grade | IP20 | |||
Others | Cooling mode | Forced air cooling |
Application industries
Model AS400 4T- | 02P2 | 03P7 | 05P5 | 07P5 | 0011 | 0015 | 18P5 | 0022 | 0030 | 0037 | 0045 | |||||||
Maximum power of adaptive motor (kw) (Super Heavy Duty) | 1.1 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | |||||||
Maximum power of adaptive motor (kw) (Heavy Duty) | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |||||||
Rated output current (A) (Super Heavy Duty) | 3.5 | 6.2 | 11 | 15 | 21 | 27 | 34 | 41 | 52 | 65 | 80 | |||||||
Rated output current (A) (Heavy Duty) | 6.2 | 9 | 13 | 17 | 25 | 31 | 39 | 45 | 60 | 75 | 91 | |||||||
Carrier frequency (kHz) | 2-8Khz (modified in parameters) | |||||||||||||||||
Model AS400 4T- | 0055 | 0075 | 0090 | 0110 | 0132 | 0160 | 0185 | 0200 | 0220 | 0250 | 0280 | 0315 | 0355 | |||||
Maximum power of adaptive motor (kw) (Super Heavy Duty) | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | |||||
Maximum power of adaptive motor (kw) (Heavy Duty) | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | |||||
Rated output current (A) (Super Heavy Duty) | 97 | 128 | 165 | 195 | 236 | 270 | 330 | 360 | 390 | 430 | 470 | 525 | 585 | |||||
Rated output current (A) (Heavy Duty) | 112 | 150 | 180 | 216 | 260 | 300 | 370 | 390 | 426 | 480 | 520 | 600 | 650 | |||||
Carrier frequency (kHz) | 2-8KHZ (modified in parameters) | 2-5kHz(modified in parameters) | ||||||||||||||||
Supply voltage | AC 3 - phase , 380-460V, 50/60Hz | |||||||||||||||||
Permissible power fluctuation | -15%-10% (interphase unbalance rate ≤3%, add the DC reactor to improve the power factor) | |||||||||||||||||
Permissible frequency fluctuation | -5% ~ +5% | |||||||||||||||||
Instantaneous low voltage tolerance | Continue to run above 300V: continue to run 15ms when the rated voltage falls below 300V(test value at 80% load) |