Application: | High-performance Transducer, Three Phase Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Still deciding? Get samples of US$ 190/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AS180 Series VFD
Power input | Input voltage | 380-460V |
Input frequency | 45-65Hz | |
Accepting voltage change | Voltage unbalance <3% | |
Voltage drop | When the 3 phase AC380-460V, input voltage <AC300V, low voltage protection was implemented after 15ms. | |
Power output | Voltage | 0VAC ~ input voltage |
Overload grade | Stable running 40ºC,heavy load 150%, 1min | |
Efficiency (full load) | ≥0.94 | |
Output frequency accuracy | ±0.01% (digital command -10~+45ºC); ±0.1% (analog command 25±10ºC); | |
Digital input/output | Optical coupling isolation input | 7 channels, 24V high and low level can be set, input function can be defined |
Open collector output | 2 channels, output function can be defined | |
Relay output | 2 channels, normally open contacts, contact capacity: inductive, 1.5A/250VAC, output function can be defined, 2 channels, dual normally open/closed contacts, contact capacity: resistive, 4.5A/250VAC or 4.5A/30VDC; inductive: 0.4A/250VAC or 0.4A/30VDC, output function can be defined | |
Analog input/output | Analog voltage input | 2 channels, accuracy 0.1%; voltage -10V ~ +10VDC or current 0~20mA optional signal |
Analog voltage output | 2 channels, accuracy 0.1%; voltage -10V ~ +10VDC or current 0~20mA optional signal | |
Control characteristics | Carrier frequency | 1.1-8KHz; carrier frequency can be adjusted automatically according to load characters |
Frequency setting resolution | 0.01Hz (digital command), ±0.06HZ/120Hz (analog command 11 bit + no signal) | |
Running command channel | Given operation panel, given control terminal, given communication | |
Frequency given channel | Give operation panel, given digital quantity/analog quantity, given communication, given performance function. | |
Torque improved | Automatic torque improved, manual torque improved. | |
V/F curve | User defined V/F curves, linear V/F curves, and three reduced torque characteristic curves | |
Automatic voltage adjustment (AVR) | The duty ratio of output PWM signal is adjusted automatically based on the fluctuation of bus voltage, to reduce the influence of grid voltage fluctuation on output voltage fluctuation. | |
Electricity loss and keep running process | In the case of instantaneous power off, achieve uninterrupted operation through bus voltage control | |
Direct current braking capability | Brake current: 0.0~120.0% rated current | |
Characteristic function | Parameters copy | The standard operation panel can upload and download parameters and indicate copy process |
Process PID | Used for closed - loop control of process quantities | |
Common DC bus | All series can achieve the power supply of common DC bus for multiple VFD. | |
Motor protection | Rotor block, motor overload, speed limitation | |
VFD protection | Output current limited, VFD overload, IGBT overload, under voltage / over voltage of input power, under voltage / over voltage of DC bus, IGBT over heating, power faulty, analog input signal loss (loss speed reference), communication abnormality, self-tuning faulty. | |
Environment condition | Operation place | Installed vertically in a well-ventilated electrical control cabinet. Horizontal or other installation is not allowed. Cooling medium is air. Installed in environment without direct sunlight, dust, corrosive gas, flammable gas, oil mist, steam, or water. |
Environment temperature | -10 ~ +40 ºC | |
Used in diminished temperature | >40 ºC, a rise of 1 ºC, rated output current is reduced by 2%, the highest temperature is 50ºC | |
Altitude | <1000m | |
Used in diminished height | >1000m, a rise of 1000m, rated output current is reduced by 1% (up to 3000m) | |
Environment humidity | 5 ~95%, without condensation | |
Vibration (transport) | 2 ≤ f < 9Hz, 3.5 mm; 9 ≤f < 200Hz, 10m/s², 200 ≤f < 500Hz, 15m/s² | |
Vibration (installation) | 2 ≤ f < 9Hz, 0.3 mm; 9 ≤f < 200Hz, 1m/s² | |
Storage temperature | -40 ~ +70 ºC | |
Protection grade | IP20 | |
Control panel | Type | Movable |
Length | 1m, 3m | |
Connector | RJ45 | |
LCD text display | 4 row | |
LED display | 5 bit | |
Visible LED indicator | 4 pcs | |
key | 9 pcs | |
Others | Cooling way | Force air cooling |
Installation mode | Installed in cabinet with wall-mounted | |
Certificate | CE |
Technical Table
Stable running 40ºC, heavy duty loading | Dimension | ||||
VFD Model AS180 |
Rated input current (A) | Rated output current (A) | Adaptive motor (Kw) |
Overload 120% (1min) Output current (A) |
|
4T07P5 | 16 | 15 | 7.5 | 18 | A1 |
4T0011 | 21 | 20 | 11 | 24 | A2 |
4T0115 | 30.5 | 29 | 15 | 34.8 | |
4T18P5 | 38 | 36 | 18.5 | 43.2 | A3 |
4T0122 | 46 | 44 | 22 | 52.8 | |
4T0030 | 59 | 56 | 30 | 67.2 | |
4T0037 | 75 | 72 | 37 | 86.4 | A4 |
4T0045 | 94 | 90 | 45 | 108 | |
4T0055 | 115 | 110 | 55 | 132 | A5 |
4T0075 | 154 | 148 | 75 | 177.6 | |
4T0090 | 183 | 176 | 90 | 211.2 | A6 |
4T0110 | 216 | 208 | 110 | 249.6 | A7 |
4T0132 | 261 | 252 | 132 | 302.4 | |
4T0160 | 306 | 296 | 160 | 355.2 | A8 |
4T0185 | 367 | 356 | 185 | 427.2 | |
4T0200 | 402 | 390 | 200 | 468 | |
4T0220 | 427 | 415 | 220 | 498 | |
4T0250 | 481 | 468 | 250 | 561.6 | |
4T0280 | 533 | 520 | 280 | 624 | A9 |
4T0315 | 614 | 600 | 315 | 720 | |
4T0355 | 664 | 650 | 355 | 780 | |
4T0400 | 755 | 740 | 400 | 888 |
Specification | Height(mm) | Width (mm) | Depth (mm) | Weight (kg) |
A1 | 300 | 160 | 162 | 4.5 |
A2 | 379 | 222 | 182 | 8 |
A3 | 414 | 232 | 182 | 10.3 |
A4 | 530 | 330 | 288 | 29.5 |
A5 | 610 | 330 | 310 | 38 |
A6 | 750 | 430 | 350 | 79.5 |
A7 | 800 | 430 | 350 | 81 |
A8 | 880 | 500 | 350 | 112.5 |
A9 | 1030 | 630 | 370 | 170 |
A10 | 1189 | 852 | 431 | 280 |
A11 | 1359 | 852 | 431 | 310 |