Output Type: | Triple |
---|---|
Principle of Work: | Vector Control Transducer |
Switch Mode: | High Carrier Frequency PWM Control |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AS510 AFE VFD products, with the use of advanced controllable rectification technique and coupled with LCL filter, achieves the active rectification and provides constant DC power and energy feedback for the system. One or more VFD units may operate in the DC bus to form the multi-motor drive system of four quadrant operation, providing an ideal solution for the motor control application in various occasions.
* Technical features
* Application industries
Harmonic suppression occasions: pump, wind turbine and compressor
Energy feedback occasion:crane, winch, pipeline, hoist, test bench, turbine motor and other complex drive systems.
Model and Technical data
Dimensions | VFD Model AS510 | Rated output power (Kw) | Rated output current (A) | Rated input current (A) |
A1 | 4T0030 | 41 | 62 | 65 |
A2 | 4T0055 | 80 | 122 | 128 |
A3 | 4T0110 | 150 | 228 | 240 |
A4 | 4T0185 | 220 | 334 | 352 |
4T0220 | 266 | 403 | 426 | |
A5 | 4T0280 | 325 | 492 | 520 |
4T0350 | 405 | 615 | 650 | |
A6 | 4T0450 | 511 | 775 | 820 |
Stable operation at 40ºC,heavy load |
Product model AS510 | 4T0030 | 4T0055 | 4T0110 | 4T0185 | 4T0220 | 4T0280 | 4T0350 | 4T0450 | |
Adaptive power (KW) | 30 | 55 | 110 | 185 | 220 | 280 | 350 | 450 | |
Rated Capacity (KVA) | 38 | 76 | 142 | 209 | 253 | 308 | 358 | 487 | |
Rated output current(when DC is 660V) A | 58 | 115 | 215 | 316 | 383 | 467 | 584 | 737 | |
Rated input current (AC) A | 65 | 128 | 240 | 352 | 426 | 520 | 650 | 820 | |
Controllable Voltage range | 600-740V | ||||||||
Power input | Input power | 380-460V (±15%), three-phase power | |||||||
Input frequency | 45-65HZ | ||||||||
Instantaneous power drop | Under voltage protection when the input voltage is less than AC300V in the three-phase power supply AC380-460V | ||||||||
Control characteristics | Control mode | Vector control | |||||||
Input power factor | Above 0.95 (under rated current | ||||||||
Harmonic | Less than 4% (under rated current) | ||||||||
Overload capacity | 150%, 1min | ||||||||
Carrier frequency | 4-6KHZ | ||||||||
Environmental conditions | Usage occasion | Keep out of direct sunlight, dust, corrosive gases, combustible gases, oil mist, water vapor or dropping water. | |||||||
Environmental temperature | -10 ~ +40ºC | ||||||||
Altitude | 1000m | ||||||||
Environmental humidity | 5~95%, no condensation | ||||||||
vibration | 3.5m/s², 2~9HZ; 10m/s², 9~120HZ; | ||||||||
Storage temperature | -40~+70ºC | ||||||||
Protection grade | IP20 for 4T055 and below; IP30 fro 4T110 and above | ||||||||
Others | Cooling mode | Forced air cooling | |||||||
certification | CE |
Specification | Height(mm) | Width (mm) | Depth (mm) | Weight (kg) |
A1 | 300 | 160 | 162 | 4.5 |
A2 | 379 | 222 | 182 | 8 |
A3 | 414 | 232 | 182 | 10.3 |
A4 | 530 | 330 | 288 | 29.5 |
A5 | 610 | 330 | 310 | 38 |
A6 | 750 | 430 | 350 | 79.5 |
A7 | 800 | 430 | 350 | 81 |
A8 | 880 | 500 | 350 | 112.5 |
A9 | 1030 | 630 | 370 | 170 |
A10 | 1189 | 852 | 431 | 280 |
A11 | 1359 | 852 | 431 | 310 |